Maintenance of Pole Mounted Circuit Breaker as Medium Voltage Network Protection at PT.XYZ


Pemeliharaan Pole Mounted Circuit Breaker Sebagai Proteksi Jaringan Tegangan Menengah di PT. XYZ


  • (1) * Faisal Faris              
            Indonesia

  • (2)  Arief Wisaksono            Universitas Muhammadiyah Sidoarjo  
            Indonesia

    (*) Corresponding Author

Abstract

The increasing demand for electricity requires PT. XYZ to provide a sufficient, reliable, safe, high-quality, and efficient source of electrical energy. In serving customers, especially those in the Medium Voltage (MV) category, good protective equipment is needed. However, conventional protective equipment often tends to be large, requires ample land space, and installation is time-consuming. This research covers variables such as contact resistance measurement, PMT (Power Circuit Breaker) synchronism testing, and insulation resistance measurement. Using the Research and Development (R&D) method, the results of maintenance on the 20 kV PMT at PMCB KPI P. Sidomulyo, Buduran Subdistrict, revealed that the contact resistance measurement values for phases R, S, and T were below 100 µΩ, indicating good contact resistance. PMT synchronism testing produced time difference values that were within the permissible standard limits. The time difference when opening (open) was 0.7 ms, while when closing (close), it was 1.05 ms. Insulation resistance measurements showed values that met the standards, which were above 20 MΩ. Based on the research results, PMCB KPI P. Sidomulyo, Buduran Subdistrict, can still be considered suitable for use. With good protective equipment and measurements that meet the standards, the use of 20 kV PMT can remain efficient and safe for consumers.

Downloads

Download data is not yet available.

References

[1] J. B. Timur and B. Dan Nusa Tenggara Desember, “Kajian Pemanfaatan Pole Mounted Circuit Breaker Sebagai Switching Dan APP Pelanggan TM.”
[2] “Enhanced Reader.”
[3] C. Pembelajaran, M. Kegiatan, S. Capaian, and P. M. Kegiatan, “Kegiatan Belajar 4 : Alat Pengukur dan Pembatas (APP)”.
[4] “897-Article Text-4061-1-10-20230212”.
[5] Rizal A. Duyo, “ANALISIS PENYEBAB GANGGUAN JARINGAN PADA DISTRIBUSI LISTRIK MENGGUNAKAN METODE FAULT TREE ANALYSIS DI PT. PLN (PERSERO) RAYON DAYA MAKASSAR”.
[6] “BAB II TINJAUAN PUSTAKA 2.1 Sistem Tenaga Listrik”.
[7] M. L. Ali;, “ANALISA KINERJA PROTEKSI PMCB ( POLE MOUNTED CIRCUIT BREAKER ) DAN RECLOSER DI PT.PLN (PERSERO) DISTRIBUSI JAWA TIMUR ULP KRAKSAAN PADA PENYULANG WANGKAL,” 2019, Accessed: Sep. 26, 2023. [Online]. Available: //digilib.unuja.ac.id%2Findex.php%3Fp%3Dshow_detail%26id%3D18917
[8] “Okpatrioka STKIP Arrahmaniyah”.
[9] “View of Analisis Pengukuran Tahanan Kontak dan Tahanan Pertanahan Pada Pemutus Tenaga (PMT).” Accessed: Sep. 20, 2023. [Online]. Available: https://senter.ee.uinsgd.ac.id/repositori/index.php/prosiding/article/view/senter2021p18/senter2021p18pdf
[10] Z. Yusniati and T. Pelawi, “PENGUKURAN RESISTANSI ISOLASI INSTALASI PENERANGAN BASEMENT PADA GEDUNG RUMAH SAKIT GREND MITRA MEDIKA MEDAN,” Online.
[11] Edi Suhardi Rahman, Muhammad Yusuf Mappeasse, and Hasrul, “STUDI PENGUJIAN KESEREMPAKAN PEMUTUS TENAGA (PMT) 150 KV MENGGUNAKAN BREAKER ANALYZER DI GARDU INDUK”.
[12] P. Darminto, “Analisis Pengukuran Tahanan Kontak dan Tahanan Pertanahan Pada Pemutus Tenaga,” 2022.
[13] A. Makkulau, N. Pasra, ; Rifaldi, R. Siswanto, T. Elektro, and S. Tinggi Teknik -Pln, “PENGUJIAN TAHANAN ISOLASI DAN RASIO PADA TRAFO PS T15 PT INDONESIA POWER UP MRICA.”
Picture in here are illustration from public domain image (License) or provided by the author, as part of their works
Published
2024-03-13
 
How to Cite
[1]
F. Faris and A. Wisaksono, “Maintenance of Pole Mounted Circuit Breaker as Medium Voltage Network Protection at PT.XYZ”, PELS, vol. 5, pp. 245 - 250, Mar. 2024.

Most read articles by the same author(s)

1 2 > >>